5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
8-90
timers pacing Isa-group
Adjusts how OSPFv3 groups LSAs for the purposes of a periodic refresh. OSPFv3 will refresh self-
originated LSAs around once every 30 minutes. When OSPFv3 refreshes LSAs, it takes into
consideration all self-originated LSAs with an age from 1800 to 1800 plus the pacing group size.
Grouping the LSAs for a refresh allows OSPFv3 to combine the refreshed LSAs into a minimal number of
LS Update packets, which makes LSA distribution more efficient.
When OSPFv3 originates a revised or new LSA, it will select a random refresh delay for that LSA.
OSPFv3 then refreshes the LSA when the refresh delay expires. Through the selection of a random
refresh delay, OSPFv3 avoids the need to refresh a large number of LSAs all at once, even in the event
that a large number of LSAs are originated at one time.
The window in which LSAs are refreshed is measured in seconds, with the allowed range for the pacing
group window being 10 to 1800 seconds.
The no command resets the LSA Group Pacing parameter back to the factory default value of 60
seconds.
timers pacing lsa-group seconds
no timers pacing lsa-group
Parameters
seconds
Default
The default is 60 seconds.
Command Mode
Router OSPFv3 Config
8-91
timers throttle spf
The spf-hold value specifies the amount of delay for the initial "wait interval". In the event that an SPF
calculation is not scheduled within the current "wait interval", then the next SPF calculation is scheduled
at a delay defined by spf-start. If an SPF calculation has been scheduled within the current "wait interval",
then the "wait interval" is set to a value equal to two times the current "wait interval" until the "wait interval"
hits the maximum time in milliseconds as specified by spf-maximum. Subsequent wait times will then
remain at the maximum until such time as the values are reset or an LSA is received in between SPF
calculations.
The no command resets the SPF throttling parameters back to the factory default values.
timers throttle spf spf-start spf-hold spf-maximum
no timers throttle spf
Parameters
spf-start
Set width of the window for grouping LSAs for refresh (10-1800).
Indicates the SPF schedule delay in milliseconds when no SPF
calculation has been scheduled during the current "wait interval". Value
range is 1 to 600000 milliseconds.