Dataflt (Card Provisioning Failure) - Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
DATAERR
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a warm reset on the Equipment Controller. This will cause a Equipment
2
Controller switch in a redundant configuration.
...................................................................................................................................................................................................
Perform a cold reset on the alarmed card.
3
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Delete the services and de-provision the alarmed card. Re-provision the card with the
4
same parameters as was previously done.
...................................................................................................................................................................................................
5
Reseat the alarmed card. Refer to
...................................................................................................................................................................................................
Replace the alarmed card. Refer to
6
E
N D
O F
...................................................................................................................................................................................................
DATAFLT

DATAFLT (Card Provisioning Failure)

The Card Provisioning Failure may be raised if a card rejects the provisioning parameters
given to it by the Equipment Controller upon a reset or due to a user provisioning action.
This may indicate a discrepancy on the database of the Equipment Controller or may
indicate a problem with the software.
The card, against which the DATAFLT condition is raised, may not be able to provide
services since some or all of the provisioning parameters were rejected.
Severity
Service affecting?
....................................................................................................................................................................................................................................
2-60
config card
Select the card, click the
S T E P S
Major
No
card type shelf slot
reset cold
Reboot
tab, select
"Reseating a Card" (p.
"Replacing System Components" (p.
DATAERR (Data Error or Timeout)
Cold Reboot
>
Submit
.
3-19).
3-20).
1830 PSS-36/PSS–32/PSS-16/PSS-4