Trouble-clearing procedures
....................................................................................................................................................................................................................................
ENV
ENV (Environmental Input [1-8] active)
The ENV condition relates to housekeeping. The ENV inputs are user-defined sensors
that can be arbitrarily configured to set an alarm for such as actions as opening a door, or
a smoke detector.
...................................................................................................................................................................................................
Define the environmental input defined by using one of the following commands:
1
CLI
WEBUI
E
N D
O F
...................................................................................................................................................................................................
EXCESSLOAD
EXCESSLOAD (Excessive Current Load)
The EXCESSLOAD condition indicates the last card inserted draws an additional current
load on the shelf that exceeds the current limit of the equipped power filters. The pack in
the affected slot will not initialize and operate.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Remove the pack that is reporting the alarm.
1
....................................................................................................................................................................................................................................
2-88
config alm
Select
Reports
S T E P S
Critical
Yes
112SCA1, 112SCX10, 11DPE12E, 11DPM12, 11STAR1,
11STMM10, 11STGE12, 43STA1P, 43STX4, 43STX4P, 4DPA2,
4DPA4, A2325A, ALPHG, AHPHG, AHPLG, ALPFGT,
AM2017B, AM2325B, CWR, Equipment Controller, OPS, OSCT,
SVAC, WTOCM
>
>
.
Alarm List
Total
ENV (Environmental Input [1-8] active)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011