Trouble-clearing procedures
PRCDRERR
....................................................................................................................................................................................................................................
PRCDRERR (Subtended shelf cannot be assigned a shelf id)
The maximum supported number of shelves would be exceeded by a newly discovered
shelf. The maximum for universal shelves is 8, the maximum for SFD44 shelves is 8, and
the maximum for DCM shelves is 16. The maximum numbers include all provisioned
shelves, whether physically connected or not.
The network element supports up to seven subtended universal shelves. These are given
subtended shelf IDs two through eight, and the rotary dial on the backplane must be set
equal to the shelf ID.
If a subtended shelf is discovered with an invalid or non-unique rotary dial setting, then
no shelf ID can be assigned to that shelf and this alarm is raised.
Severity
Service affecting?
Applicability
...................................................................................................................................................................................................
Review the shelf serial numbers that are assigned to the subtended shelves by displaying
1
the shelf list.
...................................................................................................................................................................................................
Display the shelf list.
2
CLI
...................................................................................................................................................................................................
View the results, and use the following commands as needed:
3
• • Disconnect the control cables to any shelf that should not be connected.
• • If any rotary dial settings are not unique, or not in the range 2-8: disconnect the
control cables to the shelf, correct the rotary dial setting, and reconnect the control
cables.
• To delete an existing shelf:
CLI
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Minor
No
SHELF
show shelf*
config shelf <shelf> type empty
S T E P S
PRCDRERR (Subtended shelf cannot be assigned a shelf id)