Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 568

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
SYNCOOS
....................................................................................................................................................................................................................................
SYNCOOS (Timing reference failed--system going into
holdover)
Corrective Action
...................................................................................................................................................................................................
Check the reference status.
1
CLI
WEBUI
E
N D
O F
...................................................................................................................................................................................................
SYNREFFAIL
SYNREFFAIL (Timing reference failed, (not Protected or
Protection not Available))
The OT port has detected an SYNCREFFAIL at the LINEREF layer. A LINEREF detects
SYNCREFFAIL when the timing reference failed, (not Protected or Protection not
Available).
Severity
Service affecting?
Applicability
Corrective Action
...................................................................................................................................................................................................
1
Check the timing reference quality and priority.
CLI
WEBUI
....................................................................................................................................................................................................................................
2-318
show card 11dpe12e shelf/slot synce lineref {1-4}
Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
S T E P S
Minor
No
LINEREFSYS
show card 11dpe12e shelf/slot synce lineref {1-4}
Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
SYNCOOS (Timing reference failed--system going into
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
holdover)
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents