Trouble-clearing procedures
MAN
....................................................................................................................................................................................................................................
MAN (Manually caused abnormal condition - card in
maintenance)
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Manually place the card in service using the following command:
CLI
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Not alarmed
No
112SA1L, 112SCA1, 112SCX10, 112SX10L, 11DPE12E,
11DPM12, 11STAR1, 11STMM10, 11STGE12, 43SCX4,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, A2325A, ALPHG,
AHPHG, AHPLG, ALPFGT, AM2017B, AM2125A, AM2125B,
AM2318A, AM2325B, CWR, DCM, ITLB, ITLU, MESH4,
MVAC, OPS, OSCT, RA2P, SFC, SFD, SFD44, SFD44B, SVAC ,
WR, WTOCM
config slot
S T E P S
MAN (Manually caused abnormal condition - card in
shelf slot
state up
maintenance)
2-179