Trouble-clearing procedures
AMPDISABLED
....................................................................................................................................................................................................................................
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Determine if there are any temperature alarms on the shelf. If so, check the airflow of the
shelf, filler card presence, and ambient air temperature. Resolve any air flow obstructions
or air-conditioner issues.
CLI
...................................................................................................................................................................................................
Perform a warm reset of the card.
2
CLI
WEBUI
...................................................................................................................................................................................................
3
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
4
Reseat the card. Refer to
...................................................................................................................................................................................................
Replace the card. Refer to
5
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
APRLINE
APRLINE (APR Active - Line)
....................................................................................................................................................................................................................................
2-30
alm
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
card type shelf slot
reset warm
tab, select
Reboot
card_type shelf slot
reset cold
tab, select
Reboot
3-19).
AMPDISABLED (Amplifier Disabled)
>
.
Warm Reboot
Submit
>
.
Cold Reboot
Submit
3-20). Follow the return
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011