Trouble-clearing procedures
INVALIDEGRESS
....................................................................................................................................................................................................................................
INVALIDEGRESS (Invalid or no egress port defined)
The INVALIDEGRESS condition is raised when a unidirectional AM2125A, AM2125B
or RA2P has an external topology provisioned on LineIn port, but no associated opposite
direction port is defined.
Severity
Service affecting?
Applicability
...................................................................................................................................................................................................
Check the topology between ingress and egress LD (if there is egress LD). Check the
1
external topology for the ingress LD line port. If the topology is missing, add the
topology and re-run the egress adjustment.
...................................................................................................................................................................................................
2
Ensure that Opposite Direction Port field is provisioned correctly for the egress LD
Lineout port.
CLI
WEBUI
E
N D
O F
...................................................................................................................................................................................................
INVALIDTHRESHOLD
INVALIDTHRESHOLD
The OPS pack currently has an invalid switch threshold value provisioned. The threshold
must be greater than -30 dBm to clear the condition.
When a cross-connect is added for the first time, the INVALIDTHRESHOLD alarm is
raised for ports A and B, and then clears after a few seconds. If the XC is deleted and
reentered, then the INVALIDTHRESHOLD alarms is not raised.
Severity
Service affecting?
....................................................................................................................................................................................................................................
2-118
Critical
Yes
AM2125A, AM2125B, RA2P
config interface shelf/slot/port oppDirection
From the Equipment Tree, select the OPS card, and select the desired port (A
or B).
S T E P S
Minor
No