Trouble-clearing procedures
FRCDWKSWBK
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Clear the forced switch.
2
CLI
E
N D
O F
...................................................................................................................................................................................................
FRCDWKSWPR
FRCDWKSWPR (Forced switch to protection)
This is a standing condition indicating a forced switch to protect is active.
The forced switch of working facility/equipment to protection condition is raised when a
user initiates a forced switch to protect request within a protection group. A forced switch
to protect forces traffic onto the protect facility/equipment unless the protect facility is in
the signal fail state. A forced switch to protect also prevents reversion to the working path
from occurring. Clearing the forced switch clears the condition.
If reversion is enabled, a switch occurs to the work facility immediately after the forced
switch has cleared.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Display the protection group for the associated shelf slot/port.
CLI
....................................................................................................................................................................................................................................
2-104
config aps group <group> clearSwitch
S T E P S
Not alarmed
No
11STAR1, 11STMM10, 11STGE12, 4DPA4, OPS
config aps group <group> detail
FRCDWKSWBK (Forced switch to working)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011