Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 311

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
DATAFLT
....................................................................................................................................................................................................................................
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Determine if there is a software mismatch on the NE. If so, resolve the software issue
1
first. The NE should be running with a committed software load.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a warm reset on the card that has the DATAFLT condition raised against it:
2
CLI
WEBUI
...................................................................................................................................................................................................
Perform a warm reset on the Equipment Controller. This will cause a Equipment
3
Controller switch in a redundant configuration.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
112SA1L, 112SCA1, 112SCX10, 112SX10L, 11DPE12E,
11DPM12, 11STAR1, 11STMM10, 11STGE12, 43SCX4,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, AHPHG, AHPLG,
ALPHG, ALPFGT, AM2017B, AM2125A, AM2125B, AM2318A,
CWR, CWR8-88, Equipment Controller, FLC, MESH4, MT0C,
MVAC, OPS, OSCT, RA2P, SVAC, WR, WTOCM
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
show software upgrade status
alm
Select
Administration
config card
Select the card, click the
3-19).
>
Software
>
Upgrade
card type shelf slot
reset warm
tab, select
Reboot
DATAFLT (Card Provisioning Failure)
and view the Status field.
>
.
Warm Reboot
Submit
2-61