Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 510

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
PWRADJFAIL
....................................................................................................................................................................................................................................
To delete optical channel services:
CLI
...................................................................................................................................................................................................
Perform a cold reset on the SFD40/SFD44B.
4
CLI
WEBUI
...................................................................................................................................................................................................
5
When the temperature alarm is cleared, re-provision the optical channel service and
continue with
...................................................................................................................................................................................................
Check the reason for the failure at the ingress LD card that has raised the PWRADJFAIL
6
alarm.
CLI
WEBUI
...................................................................................................................................................................................................
7
If the reason is a lack of communication to the upstream NE, resolve the communication
issue prior to resolving the PWRADJFAIL alarm. Ensure the NE with the PWRADJFAIL
alarm can communicate with the upstream NE.
CLI
...................................................................................................................................................................................................
Retrieve the optical power levels at the receive port of the LD card where the alarm is
8
raised.
CLI
....................................................................................................................................................................................................................................
2-260
config xc src_shelf/slot/port dest_shelf/slot/port freq
state down
config xc src_shelf/slot/port dest_shelf/slot/port freq
delete
config card card type shelf slot reset cold
Select the card, click the
Step
6.
config powermgmt
In the Equipment Tree, select the LD card and then its affected port.
Click the Power Management tab.
telnet IP address of upstream NE
show interface <shelf slot port> wave in, out
PWRADJFAIL (Power Adjustment Failure)
tab, select
Reboot
Cold Reboot
ingress| egress shelf slot
>
.
Submit
detail
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents