Trouble-clearing procedures
TIM
....................................................................................................................................................................................................................................
TIM
TIM (Trace Identifier Mismatch)
The TIM condition is typically raised when the received section trace does not match the
expected section trace. This may be caused by either an error in the provisioning of the
section trace, or an error in the fibering. For the Trail Trace Identifier Mismatch condition
(Network Ports) the cause would be an error in the fibering at the near end or the far end.
This alarm is raised if:
• There is an error in the configuration of the trace at the transmit or receive end (TIM)
• There is an error in the fibering of compatible SONET sources (TIM or TTI
Mismatch)
• The trace is not being generated (TIM or TTI Mismatch)
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
TIM (Trace Identifier Mismatch)