Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 281

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
APRLINE
....................................................................................................................................................................................................................................
The automatic power reduction mode has been invoked on the optical line. The APRLINE
condition is reported against the egress amplifier when a LOS is detected on the ingress
amplifier, or as a result of OSC failure, when the span is equipped with an RA2P. The
APRLINE condition is raised against the output port of the egress amplifier. If the egress
is a unidirectional amplifier (AM2125A, AM2125B), the condition is raised against the
Line port. If the egress is a bidirectional amplifier, the condition is raised against the Sig
port.
Severity
Service affecting?
Applicability
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Determine the ingress amplifier that is connected to the egress amplifier reporting the
1
APR condition.
CLI
WEBUI
...................................................................................................................................................................................................
2
Confirm the LOS condition on the ingress amplifier.
CLI
TL1
...................................................................................................................................................................................................
3
Check that the OSCs at both ends of the span are set to OC3.
...................................................................................................................................................................................................
Proceed to
4
...................................................................................................................................................................................................
5
The APRLINE condition will automatically clear up to 100 seconds after the ingress LOS
condition has been cleared.
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Major
Yes
ALPHG, AHPHG, AHPLG, ALPFGT, AM2017B, AM2125A,
AM2125B, AM2325B, RA2P
show interface topology
Select
Connections
alm
RTRV-ALM-OTS
"LOS" (p. 2-148)
to clear the LOS condition.
S T E P S
>
.
Physical Topology
APRLINE (APR Active - Line)
2-31