Trouble-clearing procedures
MISMATCH
....................................................................................................................................................................................................................................
If...
it is a DCM card,
...................................................................................................................................................................................................
3
If the inserted card is the incorrect type, remove the card and insert one that matches the
provisioned type for the slot.
If the provisioning is incorrect, then reconfigure to make the provisioning match the card:
CLI
WEBUI
If the provisioning is correct and the card is of a matching type, then there is an issue with
the card itself. Continue with
...................................................................................................................................................................................................
4
Perform a warm reset of the card.
CLI
WEBUI
...................................................................................................................................................................................................
5
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
1.
config slot <shelf slot port> state down
command for all client ports on the card and then the network port.)
2.
config slot <shelf slot> state down
3.
config slot <shelf slot> type empty
4.
config slot <shelf slot> type <correct type>
1. Select the slot of the desired card, and on the Card Properties window,
select
Out of Service
2. Click the Delete tab, select Delete this card, and click
3. On the Provision Card window, select the desired card type in the
Provisioned Type field, and click
Step
4.
card_type shelf slot
config card
Select the card, click the
card_type shelf slot
config card
Select the card, click the
Then...
ensure that it is the correct compensation
distance.
in the Primary State field, and click
.
Submit
reset warm
Reboot
tab, select
Warm Reboot
reset cold
Reboot
tab, select
Cold Reboot
MISMATCH (Card Mismatch)