Trouble-clearing procedures
MAN
....................................................................................................................................................................................................................................
MAN (Manually caused abnormal condition - port in
maintenance)
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Manually place the port in service using the following command:
1
CLI
E
N D
O F
...................................................................................................................................................................................................
MAN (Logical removal performed on a timing reference)
The MAN condition occurs when the OT port has detected a MAN at the LINEREF layer,
which indicates that a logical removal was performed on a timing reference.
Severity
Service affecting?
Applicability
To clear the condition, check with the assigning of connection between the LINEREF and
the physical port.
....................................................................................................................................................................................................................................
2-180
Not alarmed
No
112SCA1, 112SCX10, 11STAR1, 11STMM10, 11STGE12,
AM2017B, AM2325B, AHPHG, AHPLG, ALPHG, ALPFGT,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, CWR8, MVAC,
OPS, OSCT, RA2P, SFC, SFD, SVAC, WTOCM
config interface <shelf slot port> state up
S T E P S
Minor
No
LINEREFSYS
MAN (Manually caused abnormal condition - port in
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
maintenance)