Trouble-clearing procedures
PWRSUSP
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Replace the egress line LD pack.
9
E
N D
O F
...................................................................................................................................................................................................
PWRTILTSUSP
PWRTILTSUSP (Amplifier gain tilt adjustments suspended)
The PWRTILTSUSP condition indicates that the amplifier gain tilt adjustments have been
suspended.
Severity
Service affecting?
Applicability
Corrective Action
Note: The PWRTILTSUSP condition notifies the user that alarms present in the
system have caused the automatic adjustments to be suspended.
This procedure details the corrective action for clearing the PWRTILTSUSP condition.
...................................................................................................................................................................................................
1
Identify and correct current transmission or equipment failures in the optical line.
E
N D
O F
...................................................................................................................................................................................................
RAMANSUP
RAMANSUP (Raman Suppress - Line)
The LINE port on externally facing line cards has detected a Loss Of Signal on a line that
has an external Raman Amplifier connected. This RAMANSUP alarm would have an
associated LOS alarm is raised if the power measured at the port input drops below a
threshold.
....................................................................................................................................................................................................................................
2-276
S T E P S
Minor
No
A2325A, AHPHG, AHPLG, ALPHG, A2325A, AM2017B,
AM2125A, AM2125B, AM2325B
S T E P S
PWRSUSP-CWR8 (Power management suspended)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011