Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 441

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
MISMATCH
....................................................................................................................................................................................................................................
MISMATCH (Shelf Mismatch)
The detected DCM or SFD44 shelf serial number does not match the provisioned serial
number.
Severity
Service affecting?
Applicability
Corrective Action
...................................................................................................................................................................................................
Review DCM and SFD44 shelf serial numbers and make corrections as needed.
1
...................................................................................................................................................................................................
2
Display the shelf list.
CLI
...................................................................................................................................................................................................
3
View the results, and use the following commands as needed:
To change a DCM/SFD44 shelf serial number:
CLI
WEBUI
To create a new shelf:
CLI
WEBUI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
SHELF
show shelf*
config shelf <shelf> serialnum <string>
In the Equipment Tree, select the desired DCM/SFD44 shelf.
Enter the value in the Serial Number field.
Select
Delete this Shelf
config shelf <shelf> type dcm
or
config shelf <shelf> type sfd44
In the Equipment Tree, select System.
Click the Create Shelf tab.
Enter the desired values (DCM or SFD44) on this window, and click
.
Submit
, and click
Submit
.
MISMATCH (Shelf Mismatch)
2-191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents