Trouble-clearing procedures
TIM
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a cold reset of the card on the local card where the TIM condition is raised. If the
5
problem does not clear then perform a cold reset on the far-end card associated with the
local card raising the TIM condition.
CLI
WEBUI
...................................................................................................................................................................................................
6
Reseat the alarmed card. If the problem does not clear then reseat the associated far end
card. Refer to
...................................................................................................................................................................................................
Replace the alarmed card. If the problem does not clear then replace the associated
7
far-end card. Refer to
repair process in the Customer and Product Support guide to return the faulty card to an
authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
TIMEGR
TIMEGR (Egress Trail Identifier Mismatch - ODU)
The TIM condition is typically raised when the received section trace does not match the
expected section trace. The TIMEGR alarm is a TIM condition detected exiting the client
port. This may be caused by either an error in the provisioning of the section trace, or an
error in the fibering. For the Trail Trace Identifier Mismatch condition (Network Ports)
the cause would be an error in the fibering at the near end or the far end.
This alarm is raised if:
• There is an error in the configuration of the trace at the transmit or receive end (TIM)
• There is an error in the fibering of compatible SONET sources (TIM or TTI
Mismatch)
• The trace is not being generated (TIM or TTI Mismatch)
Severity
Service affecting?
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
CR
Yes
Trail Trace Identifier Mismatch (Network Ports)
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
Cold Reboot
>
Submit
.
3-20). Follow the return and
2-325