Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 597

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
VCGLOA
....................................................................................................................................................................................................................................
A loss of alignment has occurred in the virtual concatenation (mapping of a 1GbE signal
from a 11STMM10 client port into 24 STS-1s for 11STMM10 network port
transmission).
The VCGLOA alarm is masked by any higher level SONET section or line alarms, so if
this alarm is present it means that the 11STMM10 is receiving a valid, error-free OC-48
network signal.
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Verify the end-to-end path of the 11STMM10 circuit to ensure that the card reporting the
alarm is connected to a 11STMM10 on the far end. A possible cause of this alarm is if the
card is connected to another valid OC-48 signal generated by a test set or SONET
interface, but which does not include two GFP encapsulated 1GbE signals. Perform a
warm card reset of the 11STMM10 reporting the alarm.
CLI
WEBUI
...................................................................................................................................................................................................
2
Perform a warm reset of the card of the far end 11STMM10 that is connected to the
11STMM10 reporting the alarm.
CLI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
11STMM10
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
3-19).
card type shelf slot
reset warm
Reboot
tab, select
card type shelf slot
reset warm
VCGLOA (Loss of alignment)
Warm Reboot
>
Submit
.
2-347

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents