Trouble-clearing procedures
LOS
....................................................................................................................................................................................................................................
CWR Input LOS
The SIG port on one of the CWR8 cards has detected a Loss Of Signal. The LOS alarm is
raised if the power measured at the port input drops below a threshold.
This may be caused by the following reasons:
• A misconnected, damaged or dirty fiber
• The received power may not be within the acceptable range
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Query the receive power on the port where the LOS condition is present.
1
CLI
WEBUI
...................................................................................................................................................................................................
2
Verify that the fiber is the correct type (multi-mode / single mode) and that the other end
of the fiber is connected properly.
...................................................................................................................................................................................................
Ensure that the administrative state of the port is Admin Up. If it is Up, then toggle the
3
administrative state from UP-->DOWN-->UP.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
CWR8, CWR8-88
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
show interface <shelf slot port>
From the Equipment Tree, select the card, and select the desired port.
3-19).
CWR Input LOS
2-155