Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 353

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
FRCDSWTIMREF
....................................................................................................................................................................................................................................
Corrective Action
...................................................................................................................................................................................................
Clear force switch.
1
CLI
WEBUI
E
N D
O F
...................................................................................................................................................................................................
FRCDWKSWBK
FRCDWKSWBK (Forced switch to working)
This is a standing condition indicating that a forced switch back to the working is active.
The forced switch of working back to working condition occurs when a user initiates a
forced switch to work request within a protection group. A forced switch to working
forces traffic onto the working facility/equipment unless the working facility is in the
Signal-Fail state.
Clearing the manual switch clears the condition. In the absence of other outstanding
requests, a cleared forced switch back to work leaves the switch position on work.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Display the protection group for the associated shelf/slot/port.
1
CLI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
show card 11dpe12e shelf/slot synce
Select the 11DPE12E card in the Equipment Tree.
Select System Timing.
S T E P S
Not alarmed
No
11STAR1, 11STMM10, 11STGE12, 4DPA4, OPS
show aps group <group> detail
FRCDSWTIMREF (Forced Switch Timing Reference)
2-103