Trouble-clearing procedures
ALLCHANMISS-OUT
....................................................................................................................................................................................................................................
No C-Band channels are detected leaving from (transmitted by) the amplifier SIG port,
but the NE has at least one service successfully launched and the amplifier link has been
successfully received.
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
This alarm is the result of a problem internal to this NE.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Perform the procedure
1
trouble point for the lightpath. This will identify the cards and ports on this NE to look at
first during this procedure.
...................................................................................................................................................................................................
Identify the cards that are in the NE through path and confirm that all ports and cards on
2
the through path are administratively up
1. To examine the card state, enter the following command. Observe the admin state and
operational state of each of the cards along the THRU path:
CLI
2. Set any of the cards that are administratively down to up. To bring a card Admin Up:
CLI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
A2325A, AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B,
AM2325B, OSCT
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
"Path Power Trace" (p. 3-8)
show slot *
config slot
ALLCHANMISS-OUT (C-Band Loss of signal)
3-19).
to identify the probable network
shelf slot
state up
2-27