Trouble-clearing procedures
PWR
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a cold reset on the Equipment Controller that is raising the PWR condition.
4
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the Equipment Controller that is raising the PWR condition.
5
...................................................................................................................................................................................................
Replace the Equipment Controller that is raising the PWR condition. Follow the return
6
and repair process to return the card to an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
PWRADJCOMMS
PWRADJFAIL (Inter NE communication timeout blocking power
adjustment)
The Power Adjust Communications condition is raised when the ingress optical line
adjustment algorithm is unable to retrieve information from the upstream optical line to
use in the adjustment calculations. Power adjustments are run during system initial
commissioning, and during in-service power balancing (which can be manually user
triggered, auttriggered, or triggered by the commissioning and power balancing tool). The
most likely source of this condition is the upstream NE is busy processing other requests.
PWRADJCOMMS is a non-reported non-service affecting condition. If the ingress
optical line adjustment was run automatically there is no corrective action required. The
adjustment will be run again at another point in the future. If the auto triggered
adjustment is persistently resulting in PWRADJCOMMS follow the corrective actions
below.
PWRADJFAIL is a related condition: When the ingress adjustment was not run
automatically and an upstream communication timeout occurs, the PWRADJFAIL
condition is raised as a reported condition in addition to the non-reported
PWRADJCOMMS condition. This allows the user to correct the failure, if necessary,
given the context the adjustment was triggered in.
Severity
....................................................................................................................................................................................................................................
2-256
config card
Select the card, click the
S T E P S
Not reported
PWR (Power Filter 1 breaker off or voltage low) PWR (Power
card type shelf slot
reset cold
tab, select
Reboot
Filter 2 breaker off or voltage low)
>
.
Cold Reboot
Submit
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1