INVALIDTHRESHOLD
....................................................................................................................................................................................................................................
Applicability
...................................................................................................................................................................................................
1
Determine whether the threshold calculation is in automatic or manual mode.
CLI
WEBUI
...................................................................................................................................................................................................
2
Is manual switch calculation mode is in effect? (The default is auto.)
If...
no (auto is being used)
yes
...................................................................................................................................................................................................
Verify that no LOS alarms are present on the A or B input ports that would inhibit the
3
switch calculation. Proceed to
...................................................................................................................................................................................................
4
Set the threshold to a value greater than -30 dBm based on engineering rules for the
incoming channel power levels.
CLI
TLI
...................................................................................................................................................................................................
STOP! You have completed this procedure.
5
E
N D
O F
...................................................................................................................................................................................................
INVENTORYERROR
INVENTORYERROR (Card Inventory Error)
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
OPS
show interface opsa shelf/slot/port
From the Equipment Tree, select the OPS card, and select the desired port (A
or B).
Step
config interface opsa shelf/slot/port switch switchthresh
dBm value
ED-OCH:::SWTHRESH