Trouble-clearing procedures
SWEQPT
....................................................................................................................................................................................................................................
Table 2-1
Demerit
System Timing
compromised
System Timing
clock lost
System Timing
HW Failure
...................................................................................................................................................................................................
Perform a warm reset of the card on the inactive card where the alarm is raised.
3
CLI
WEBUI
...................................................................................................................................................................................................
4
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
5
Reseat the card. Refer to
....................................................................................................................................................................................................................................
2-302
Corrective Actions for Equipment Controller Demerits (continued)
Corrective Action
This demerit is raised when the inactive controller's system timing module is
not reporting the same status as the active controller's system timing module.
1. Wait for 20 seconds because this alarm should clear within 20 seconds
when the inactive system timing module is synchronized to the active
system timing module.
2. Look for system timing related alarms on any controller and
troubleshoot them.
3. If no system timing alarms are present and the demerit is still present,
replace the inactive controller.
This demerit is raised when a shelf controller determines that there is no
system timing clock from the master shelf. This demerit will cause a
controller activity switch if the inactive controller does not have this demerit
raised, but the active does.
This demerit is raised when the controller detects a failure of the circuitry
that controls and provides NE-wide timing clocks. This controller must be
replaced.
card type shelf slot
config card
Select the card, click the
card_type shelf slot
config card
Select the card, click the
"Reseating a Card" (p.
SWEQPT (Equipment Controller redundancy is
reset warm
tab, select
Reboot
Warm Reboot
reset cold
tab, select
Reboot
Cold Reboot
3-19).
8DG60888CAAA Release 3.6.0 and 3.6.1
compromised)
>
.
Submit
>
.
Submit
1830 PSS-36/PSS–32/PSS-16/PSS-4