Trouble-clearing procedures
OCHTRAILUNKNOWN
....................................................................................................................................................................................................................................
The NE has not received the OCh trail information for this Cross-Connect from the trail's
head NE. While this condition is asserted, Wavelength Tracker monitoring for this
channel is not active on this NE. This alarm may be raised for the following reasons:
• The head NE X-Connect for this OCh trail may not have been created.
• There may not be proper CN/OSPF connectivity between the NEs to allow for the
distribution of trail information.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Record the exact name used to identify the OCh trail.List the cross connects that currently
exist on-NE:
CLI
WEBUI
Search the list for the OCh trail in question. Record the exact name used for the OCh trail
(wreache spaces and case are relevant for a match).
...................................................................................................................................................................................................
Ensure that the OCh trail name as specified on this NE exactly matches the OCh trail
2
name as specified on the head NE.List the cross connects that currently exist in the
network.
CLI
...................................................................................................................................................................................................
3
Search the list for the OCh trail in question. Compare any names for the exact name
recorded in the
If...
the name is misspelled,
....................................................................................................................................................................................................................................
2-222
Minor
No
A2325A, AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B,
AM2125A, AM2125B, AM2325B, OSCT, RA2P
show xc brief
Select
Connections
>
show ochtrail network
Step
1.
OCHTRAILUNKNOWN (Unknown OCH Trail for x-connect)
Cross-Connects
.
Then...
recreate the appropriate connection with the
appropriate name.