Trouble-clearing procedures
OCHTRAILDUP
....................................................................................................................................................................................................................................
OCHTRAILDUP (Duplicate OCh trail name)
Severity
Service affecting?
Applicability
Corrective Action
The alarm will list the IP address and shelf, slot, port for the other NE sourcing the same
OCh Trail name.
...................................................................................................................................................................................................
1
Confirm that there is a NE with the IP address that is alledgedly sourcing the duplicate
OCh Trail. If the IP address of the sourcing NE was recently changed then this alarm
resolves itself within one hour.
...................................................................................................................................................................................................
2
If
Step 1
name.
...................................................................................................................................................................................................
Recreate the connection (across the network) for the path. This involves deleting that trail
3
and recreating it with a different name.
E
N D
O F
...................................................................................................................................................................................................
OCHTRAILUNKNOWN
OCHTRAILUNKNOWN (Unknown OCH Trail for x-connect)
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Minor
No
112SA1L, 112SCA1, 112SCX10, 112SX10L, 43SCX4, 43STA1P,
43STX4, 43STX4P, 4DPA4, MVAC, SVAC, Cross-connect
did not resolve the problem, then choose which connection should have a new
S T E P S
OCHTRAILDUP (Duplicate OCh trail name)
2-221