Trouble-clearing procedures
HIBER
....................................................................................................................................................................................................................................
This may be caused by the following reasons:
• Damaged or dirty fiber connected to the far-end client equipment receiver
• The received power may not be within the acceptable range on local port input
• Damaged or dirty transmitter inside pluggable module on the far end
Severity
Service affecting?
Applicability
Corrective Action
This procedure details the corrective action for clearing a HIBER condition on an OT
port.
...................................................................................................................................................................................................
1
Retrieve power level reading on the local OT port.
...................................................................................................................................................................................................
Clean the fiber.
2
...................................................................................................................................................................................................
3
If cleaning the fiber does not clear the problem, replace the fiber.
...................................................................................................................................................................................................
If the power level is within the operating range, check for pluggable module alarms.
4
...................................................................................................................................................................................................
5
Replace the pluggable module.
E
N D
O F
...................................................................................................................................................................................................
HIGAIN
HIGAIN (Amplifier Out of Operational Range: Gain too High)
....................................................................................................................................................................................................................................
2-110
Critical
Yes
11DPE12, 11DPE12E, 11QPA4, 11STAR1, 11STGE12
S T E P S
HIBER (High BER)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1