Supporting procedures
Replacing System Components
....................................................................................................................................................................................................................................
config database backup
...................................................................................................................................................................................................
3
Replace the Equipment Controller.
The Equipment Controller will have a DBINVALID alarm active after the reboot has
completed.
...................................................................................................................................................................................................
4
If...
the Equipment Controller is new from the
factory or does not contain the desired
software release,
the Equipment Controller has the current
desired software,
...................................................................................................................................................................................................
To configure or verify the OAMP port details, type
5
config interface usrpnl oamp ip
A warning is displayed:
WARNING: Changing the OAMP ethernet port IP address may result
in a loss of IP connectivity to this and other network elements.
Type
yes
...................................................................................................................................................................................................
To configure or verify the TID, type
6
...................................................................................................................................................................................................
7
To configure or verify the loopback IP address, type
config interface loopback ip
A warning is displayed:
WARNING: Changing the loopback IP address will result in a warm
reset of this network element.
Type
yes
...................................................................................................................................................................................................
To configure or verify static routes, type
8
default IP address.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
to confirm the configuration.
to confirm the configuration.
Replacing an Equipment Controller in a Nonredundant Shelf
Then...
continue with
proceed to
Step
IP address/subnet mask.
config general name
loopback IP address/subnet mask.
config cn routes default add
Step 5
13.
NE name.
gateway
3-47