Trouble-clearing procedures
MANSWTOINT
....................................................................................................................................................................................................................................
Corrective Action
...................................................................................................................................................................................................
Clear the manual switch.
1
CLI
WEBUI
E
N D
O F
...................................................................................................................................................................................................
MANWKSWBK
MANWKSWBK (Manual switch to working)
This is a standing condition indicating that a manual switch back to the working is active.
The manual switch of working back to working condition occurs when a user initiates a
manual switch to work request within a protection group. A manual switch to working
forces traffic onto the working facility/equipment unless the working facility is in the
Signal-Fail or Signal-Degrade state.
Clearing the manual switch will clear the condition. In the absence of other outstanding
requests, a cleared manual switch back to work will leave the switch position on work.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Display the protection group for the associated
1
CLI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
show card 11dpe12e shelf/slot synce
Select the 11DPE12E card in the Equipment Tree.
Select System Timing.
S T E P S
Not alarmed
No
11STAR1, 1STMM10, 11STGE12, 4DPA4, OPS
config aps group <group> detail
MANSWTOINT (Manual Switch to Internal Timing )
<shelf slot port>
.
2-183