Alarm and condition details
....................................................................................................................................................................................................................................
LSSEGR
Alarm Data
Severity Level
AID Type
Effect on Service
Alarm Entity Type
Description
Corrective Action
MAN
1 of 3
Alarm Data
Severity Level
....................................................................................................................................................................................................................................
1-116
Value/Meaning
Not alarmed
112SA1L-shelf-slot-C1
112SCA1-shelf-slot-C1
112SCX10-shelf-slot-{C1-10}
112SX10L-shelf-slot-{C1-10}
11QPA4-shelf-slot-{C1-4}
11STAR1-shelf-slot-C1
43SCX4-shelf-slot-{C1-10}
43STX4-shelf-slot- C{1-4}
NSA
112SA1L, 112SCA1: 100GbE
All other cards: 10GbE
Remote Client Loss of Synchronization
Proceed to
"LSSEGR" (p.
Value/Meaning
Not alarmed
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
LSSEGR
2-177).
Issue 1 June 2011