Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 318

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
DBUNSYNC
....................................................................................................................................................................................................................................
DBUNSYNC
DBUNSYNC (The active and standby Main EC databases are not
synchronized)
The database on the active and standby equipment controllers are not in sync.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If it does not, go to the next step.
...................................................................................................................................................................................................
Perform a warm reset of the standby controller.
1
CLI
WEBUI
...................................................................................................................................................................................................
Contact your next level of support.
2
E
N D
O F
...................................................................................................................................................................................................
DEGOTU
DEGOTU (Signal Degrade - OTU)
The DEGOTU condition is raised when a high B1 error rate is detected on the OTU2/3/4
input line or client port.
....................................................................................................................................................................................................................................
2-68
Major
No
SYSTEM
config card
Select the card, click the
S T E P S
DBUNSYNC (The active and standby Main EC databases are
card_type shelf slot
reset warm
tab, select
Reboot
not synchronized)
>
.
Warm Reboot
Submit
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents