Trouble-clearing procedures
USALS
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
If the desired behavior at the near end client port is to inject an Alarm Indication Signal
3
(AIS), idle frames, or an invalid signal and not to shut the laser off in reaction to the
upstream fault, issue the following command at the near end to change the LOSProp
(LOS Propagation) setting.
CLI
...................................................................................................................................................................................................
Using the procedure
4
nature of the fault at the far end. Look for LOS or Out of Service type alarms at the
associated client port(s).
...................................................................................................................................................................................................
5
Using the applicable procedure for the fault detected in
If the condition does not clear, perform the following steps on the near end card.
...................................................................................................................................................................................................
Perform a warm reset of the card.
6
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
7
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the card. Refer to
8
...................................................................................................................................................................................................
9
Replace the card. Refer to
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
....................................................................................................................................................................................................................................
2-342
config interface <shelf slot port> losprop injectAISL |
idleFrames | invalidSig
"Determining the Far End of a Service" (p.
card type shelf slot
config card
Select the card, click the
card_type shelf slot
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
USALS (Auto Laser Shutoff Due to Upstream Fault)
Step
4, clear the fault.
reset warm
tab, select
Reboot
Warm Reboot
reset cold
tab, select
Reboot
Cold Reboot
3-19).
8DG60888CAAA Release 3.6.0 and 3.6.1
3-10), determine the
>
.
Submit
>
.
Submit
3-20). Follow the return
1830 PSS-36/PSS–32/PSS-16/PSS-4
Issue 1 June 2011