Trouble-clearing procedures
LANLFI
....................................................................................................................................................................................................................................
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
If the LANLFI condition has been raised on a client port, verify that the source is
correctly transmitting the Ethernet signal. Refer to its manufacturer's documentation for
any corrective actions.
...................................................................................................................................................................................................
2
If the LANLFI condition has been raised on a Network port, retrieve the alarm
information from the upstream path to determine if any failure is present. If there is an
indication of failure upstream of the port where the LANLFI is raised, fix this problem
first.
...................................................................................................................................................................................................
3
Perform a warm reset on the card where the LANLFI condition is raised.
CLI
WEBUI
...................................................................................................................................................................................................
4
Perform a cold reset on the card where the LANLFI condition is raised.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
5
Reseat the card. Refer to
...................................................................................................................................................................................................
Replace the card. Refer to
6
E
N D
O F
...................................................................................................................................................................................................
LANLOS
LANLOS (LAN port LOS)
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
card type shelf slot
reset warm
Reboot
tab, select
card type shelf slot
reset cold
Reboot
tab, select
3-19).
LANLFI (Local Fault)
Warm Reboot
>
Submit
.
Cold Reboot
>
Submit
.
3-20).