Trouble-clearing procedures
BDI
....................................................................................................................................................................................................................................
BDI

Backward Defect Indication (BDI) - OTU

The OT port has detected a Backward Defect Indication at the OTUk Section layer. This
defect indicates that the peer OTUk port has detected a condition that is treated as Server
Signal Failure (conditions such as LOS, LOF or LOM would contribute to SSF)
This may be caused by the following reasons:
• A misconnected, damaged or dirty fiber on the trail between the local OTUk port
transmitter and the far end receiver
• OTS/OMS layer failure on the OCh trail
• The received power may not be within the acceptable range on the Far end input
Severity
Service affecting?
Applicability
This procedure details the corrective action for a BDI against the OT port.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Check the alarms/conditions along the OCh trail.
1
...................................................................................................................................................................................................
2
Identify the farthest upstream alarm/condition relative to the far end OTUk port.
...................................................................................................................................................................................................
Follow the procedure for clearing the identified alarm/condition.
3
...................................................................................................................................................................................................
4
If the peer OTUk port is in a client domain (this would be the case when BDI is detected
on a client OT port provisioned as OTU2), request corrective action by client operators.
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
NA
No
112SA1L, 112SCX10, 112SX10L, 11DPE12, 11DPE12E,
11QPA4, 11STAR1, 11STMM10, 11STGE12, 43SCX4, 43STA1P,
43STX4, 43STX4P, 4DPA4
S T E P S
Backward Defect Indication (BDI) - OTU
2-47