Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 413

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
LOSDCM
....................................................................................................................................................................................................................................
This may be caused by the following reasons:
• A misconnected, damaged or dirty fiber
• The received power may not be within the acceptable range
Severity
Service affecting?
Applicability
Corrective Action
This procedure details the corrective action for a LOS against the DCM port.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Query the receive power on the port where the LOS condition is present.
1
CLI
WEBUI
...................................................................................................................................................................................................
Verify that the fiber is the correct type (multi-mode/single mode) and that the other end of
2
the fiber is connected properly.
...................................................................................................................................................................................................
Ensure that the administrative state of the port is Admin Up. If it is Up, then toggle the
3
administrative state from UP > DOWN > UP.
...................................................................................................................................................................................................
4
If...
no active traffic is present on the system
the optical power is more than 15 dB below
the level coming out of the amplifier DCM
port
the optical power is within the required limits
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Critical
Yes
A2325A, AHPHG, AHPLG, ALPHG, AM2017B, AM2125A,
AM2125B, AM2325A, AM2325B
show interface <shelf slot port>
From the Equipment Tree, select the card, and select the desired port.
LOSDCM (From DCM Input LOS)
Then...
remove the fiber from the port where the LOS
is raised and measure the optical power.
using the standard optical fiber jumper
cleaning procedure, clean the fiber, and
measure the power again.
clean the receive connector on the card. If the
LOS condition is still present, the problem
may be with the card.
2-163

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents