Trouble-clearing procedures
AISL
....................................................................................................................................................................................................................................
AISL
AIS Line/MS
The card is receiving AISL from the equipment connected to the client receive port. This
condition on a network port occurs when some upstream line terminating equipment is
exhibiting a failure that sends an AISL signal to the downstream line terminating entity.
This is a non-reportable condition and the user must manually retrieve the condition from
the NE or card to view it. This alarm applies to transparent services.
Severity
Service affecting?
Applicability
....................................................................................................................................................................................................................................
2-20
Not reported
No
112SCX10, 112SX10L, 11STMM10, 43SCX4
AIS Line/MS
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1