Trouble-clearing procedures
SSF
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Check the alarms/conditions on the node located in
4
upstream from point identified in
...................................................................................................................................................................................................
Correct the problem identified in
5
...................................................................................................................................................................................................
If all power levels along the OCh trails fall within the target range, locate the fiber
6
connected directly to receiver of the port which detects SSF condition.
...................................................................................................................................................................................................
Clean the fiber.
7
...................................................................................................................................................................................................
If cleaning the fiber does not clear the problem, replace the fiber.
8
...................................................................................................................................................................................................
9
If the problem is detected on the client port of 11STAR1 OT, and the power level is
within the operating range, check for pluggable module alarms.
...................................................................................................................................................................................................
Replace the pluggable module.
10
E
N D
O F
...................................................................................................................................................................................................
SSFODU
SSFODU (Server Signal Failure - ODU)
The OT port has detected a Server Signal Failure at the ODUk level. Conditions that can
cause an SSFODU are:
• LOS-P (Loss of Signal – OTU)
• LOF (Loss of Frame – OTU)
• LOM (Loss of Multiframe – OTU)
• ODU-AIS
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1