Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 540

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
SDEG-O
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Ensure that the administrative state of the port is Admin Up. If it is Up, then toggle the
3
administrative state from UP-->DOWN-->UP.
...................................................................................................................................................................................................
4
If...
no active traffic is present on the system
the optical power is below the required
threshold for the type of pluggable module
installed
the optical power is within the required limits
...................................................................................................................................................................................................
Perform a warm reset of the card exhibiting the Loss of Frame.
5
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card exhibiting the Loss of Frame.
6
CLI
WEBUI
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
Reseat the card. Refer to
7
...................................................................................................................................................................................................
Replace the OSC SFP located inside the amplifier. See
8
(p.
3-27). Follow the return and repair process in the Customer and Product Support guide
to return the faulty pluggable module to an authorized repair center for replacement.
....................................................................................................................................................................................................................................
2-290
card type shelf slot
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
Then...
remove the fiber from the receive port where
the SDEG-O is raised and measure the optical
power.
using the standard optical fiber jumper
cleaning procedure, clean the fiber, and
measure the power again.
clean the receive connector on the card. If the
SDEG-O condition is still present, the problem
may be with the card.
reset warm
tab, select
Reboot
Warm Reboot
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
"Replacing an SFP Module"
8DG60888CAAA Release 3.6.0 and 3.6.1
SDEG-O (SUPVY Signal Degrade)
>
.
Submit
Cold Reboot
>
Submit
1830 PSS-36/PSS–32/PSS-16/PSS-4
Issue 1 June 2011
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents