Trouble-clearing procedures
EQPTDGR
....................................................................................................................................................................................................................................
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Perform a warm reset of the card.
1
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
2
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the card. Refer to
3
...................................................................................................................................................................................................
4
Replace the card. Refer to
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-76
AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B, AM2125A,
AM2125B, CWR, OPS, OSCT MESH4, MVAC, OPS, OSCT,
RA2P, WR, WTOCM
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
3-19).
card type shelf slot
reset warm
tab, select
Reboot
card_type shelf slot
reset cold
tab, select
Reboot
3-19).
EQPTDGR (Card Degrade - device)
>
.
Warm Reboot
Submit
>
.
Cold Reboot
Submit
3-20). Follow the return
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1