Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 618

1830 pss series photonic service switch
Table of Contents

Advertisement

Supporting procedures
Path Power Trace
....................................................................................................................................................................................................................................
5. If the client port is admin down then it must be brought admin up in order to clear the
alarm(s).
CLI
If this does not resolve the issue, go to 6.
6. Check that the programmed topology matches the actual topology.
7. If there are multiple alarms at the same point of interest, attempt to resolve the
amplifier alarms first.
E
N D
O F
...................................................................................................................................................................................................
Determining the Far End of a Service
Procedure
...................................................................................................................................................................................................
Check the OCh Trail name for the near end of the service.
1
CLI
Search for the <shelf/slot/port> corresponding to the card and port in question. This will
provide the information required to proceed to
...................................................................................................................................................................................................
2
Perform a trace to determine the far end of the OChTrail.
CLI
...................................................................................................................................................................................................
3
Examine the output of
E
N D
O F
...................................................................................................................................................................................................
Checking for Services on a Port
....................................................................................................................................................................................................................................
3-10
config interface <shelf/slot/ClientPort> state up
S T E P S
show xc brief
show interface <shelf/slot port> srvcActivity detail
Step 2
to determine the far end of the service.
S T E P S
Step
2.
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Procedure
Issue 1 June 2011

Hide quick links: