Trouble-clearing procedures
FEPRLF
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Check for faults on the protection side line port, or the protection side card.
2
CLI
WEBUI
...................................................................................................................................................................................................
3
If...
faults are present,
no faults are present,
E
N D
O F
...................................................................................................................................................................................................
FPGAFAIL
FPGAFAIL (FPGA Download or Programming Failure)
The FPGAFAIL alarm is raised when a corrupted firmware file is downloaded to the card
or the FPGA fails to program correctly.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a warm reset on the card where the FPGAFAIL condition is raised.
CLI
....................................................................................................................................................................................................................................
2-100
alm
Select
Reports
S T E P S
CR
Yes
112SA1L, 112SCA1, 112SCX10, 112SX10L, 11DPE12E,
11DPM12, 11STAR1, 11STMM10, 11STGE12, 4DPA2, 4DPA4,
43SCX4, 43STA1P, 43STX4, 43STX4P, ALPHG, AHPHG,
AHPLG, AM2017B, AM2125A, AM2125B, AM2318A, CWR8,
CWR8-88, MESH4, MVAC, OPS, RA2P, SVAC, WTOCM
config card
>
>
.
Alarm List
Total
Then...
proceed to the appropriate procedure for
clearing the faults.
STOP! You are done with this procedure.
card type shelf slot
reset warm
FEPRLF (Far End Protection Line Failure)