Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 290

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
APSCM
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Using the data obtained in
5
and that the protection cards are paired up.
1. Confirm that the topology matches the programmed topology.
CLI
WEBUI
2. Verify that the optical patch cord to the protect interface at the near end is connected
to the protect interface at the far end. Reconfigure and reconnect the optical patch
cords to the protect members if they are not.
3. Verify that the optical patch cord to the working interface at the near end is connected
to the working interface at the far end. Reconfigure and reconnect the optical patch
cords to the working members if they are not.
...................................................................................................................................................................................................
Enter the following commands at both the near-end and far-end NEs to confirm that the
6
card types at the near end and far end are the same.
CLI
...................................................................................................................................................................................................
7
Determine whether the card on the far-end NE is currently being upgraded.
CLI
WEBUI
If the card is in the upgrade state then wait for upgrade to complete. The upgrade is
complete when the action progress is 100% and the action status is complete. The near
end alarm should clear after the upgrade is complete.
...................................................................................................................................................................................................
If the problem persists, invoke a manual switch onto the currently active line.
8
1. Determine the currently active line:
CLI
....................................................................................................................................................................................................................................
2-40
Step 1
and
Step
show interface topology *
Select
Connections
>
slot number
show slot
show software upgrade status brief
Select
Administration
>
config aps group [x] detail
4, confirm that the working cards are paired up
Physical Topology
.
Software
>
Upgrade
and view the Status field.
8DG60888CAAA Release 3.6.0 and 3.6.1
APSCM (APS Channel Mismatch)
1830 PSS-36/PSS–32/PSS-16/PSS-4
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents