Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 649

1830 pss series photonic service switch
Table of Contents

Advertisement

Supporting procedures
Replacing System Components
....................................................................................................................................................................................................................................
An activity switch occurs if the removed card is the active Equipment Controller. When
the new Equipment Controller is inserted in the shelf, it is synchronized with the active
Equipment Controller.
...................................................................................................................................................................................................
Reconnect any Ethernet or serial cables that you removed in
7
E
N D
O F
...................................................................................................................................................................................................
To replace a Equipment Controller in a Shelf with Redundant Equipment Controllers Using the CLI
The Equipment Controller is hot-swappable, allowing in-service replacement. This
procedure is not service-affecting.
...................................................................................................................................................................................................
Retrieve which Equipment Controller is active. If the Equipment Controller that is to be
1
replaced is the active Equipment Controller for this shelf, then switch to the other
Equipment Controller. In the Equipment Tree, select the slot containing the Equipment
Controller.
1. Type
shelf.
2. Type
Controller to active, if necessary.
...................................................................................................................................................................................................
Unplug any Ethernet or serial cables that are connected to the Equipment Controller to be
2
replaced.
...................................................................................................................................................................................................
3
Remove and replace the card (see
An activity switch occurs if the removed card is the active Equipment Controller. When
the new Equipment Controller is inserted in the shelf, it is synchronized with the active
Equipment Controller.
...................................................................................................................................................................................................
Reconnect any Ethernet or serial cables that you removed in
4
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
S T E P S
to determine which Equipment Controller is active on a
show redundancy
config redundancy sw
S T E P S
Replacing an Equipment Controller in a Redundant Shelf
shelf number to switch the other Equipment
"Replacing a Card (General)" (p.
Step
5.
3-22)).
Step
2.
3-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4