Alarm and condition details
....................................................................................................................................................................................................................................
Alarm Data
Corrective Action
PLMEGR
Alarm Data
Severity Level
AID Type
Effect on Service
Alarm Entity Type
Description
Corrective Action
PRCDRERR-TOPO
Description
1 of 2
Alarm Data
Severity Level
AID Type
Effect on Service
Alarm Entity Type
Description
Corrective Action
2 of 2
Alarm Data
Severity Level
....................................................................................................................................................................................................................................
1-156
Value/Meaning
Proceed to
"PLM" (p.
2-248).
Value/Meaning
CR
43STX4-shelf-slot- C{1-4}
43STX4P-shelf-slot-{C1-C4}
SA
OTU2
Egress Payload Mismatch Indication - ODU
Proceed to
"PLMEGR" (p.
Value/Meaning
MN
SYSTEM
NSA
COM
Invalid topology
Proceed to
"PRCDRERR" (p.
Value/Meaning
MN
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
PLM
2-249).
2-250).
Issue 1 June 2011