Trouble-clearing procedures
MIXEDPFUSED
....................................................................................................................................................................................................................................
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Identify the power filter model engineered for the installation.
1
...................................................................................................................................................................................................
2
Equip the correct matching power filters.
...................................................................................................................................................................................................
Ensure the two power filters are the same type.
3
E
N D
O F
...................................................................................................................................................................................................
MMG
MMG (Mismerge)
The OT port has detected a mismerge at the MEP layer. A MEP detects mismerge when it
receives a CCM frame with a correct MEG level that is, the MEG level is the same as the
MEP's own MEG level) but incorrect MEG ID (indicating that frames from a different
service instance are merged with the service instance represented by the MEP's own MEG
ID). Such a condition is most likely caused by misconfiguration, but could also be caused
by a hardware/software failure in the network.
Severity
Service affecting?
Applicability
This alarm is raised when an MEP receives CCM frames with the correct MEG level, but
an incorrect MEG ID. The alarm is cleared when the MEP does not receive CCM frames
with the correct MEG ID.
....................................................................................................................................................................................................................................
2-194
Critical
Yes
SHELF
S T E P S
Major
No
11DPE12E
MIXEDPFUSED (Mixed types of power filters used)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011