Trouble-clearing procedures
PLMEGR
....................................................................................................................................................................................................................................
Service affecting?
Applicability
Corrective Action
This procedure details the corrective action for clearing a PLMEGR condition on an OT
port. At the end of each step wait to see if the fault clears. If not, continue with the next
step.
...................................................................................................................................................................................................
Identify the far-end peer of the local OT port where the PLM condition exists.
1
...................................................................................................................................................................................................
Check the service configuration document to determine which signal type and/or mapping
2
mode is expected to be configured on the ODUkP segment that has PLM condition.
...................................................................................................................................................................................................
Modify signal type and/or mapping mode to match the service configuration document
3
(and match on both ends of the segment).
...................................................................................................................................................................................................
4
If the source of one end of the ODUkP segment is in another operator's network (this
would be the case if there is an OTM-0.2 hand off between the 1830 PSS network domain
and the client OT network) contact the operator and resolve the mismatch in setting.
E
N D
O F
...................................................................................................................................................................................................
PRCDRERR
PRCDRERR
This section includes procedures for the following alarms:
• PRCDRERR (Subtended shelf cannot be assigned a shelf id)
• PRCDRERR-TOPO (Invalid topology)
• PRCDRERR-TOPO (Power management topology invalid)
....................................................................................................................................................................................................................................
2-250
Yes
43STX4, 43STX4P
S T E P S
PLMEGR (Egress Payload Mismatch Indication - ODU)
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011