Trouble-clearing procedures
MISMATCHMOD
....................................................................................................................................................................................................................................
Corrective Action
At the end of each step wait to see if the fault clears. If it does not, go to the next step
...................................................................................................................................................................................................
Verify the type of pluggable module that is currently inserted into the alarmed card.
1
If...
the inserted pluggable module is of correct
type by the service record but the
MODULETYPE attribute is not correct,
the inserted pluggable module is of the
incorrect type,
the inserted pluggable module is of the correct
type,
...................................................................................................................................................................................................
2
To clear the pack while it is still in service, do one of the following:
• Change the notification from a standing alarm to a transient condition, or
• Select the proper pluggable module from the supported list.
...................................................................................................................................................................................................
Remove the pluggable module and replace it with another pluggable module of the same
3
type. Perform the procedure
...................................................................................................................................................................................................
Replace the card. Refer to
4
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
MIXEDPFUSED
MIXEDPFUSED (Mixed types of power filters used)
The Mixed types of power filters alarm indicates that two different types of power filters
are provisioned in the shelf.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
"Replacing an SFP Module" (p.
"Replacing System Components" (p.
S T E P S
MISMATCH (Pluggable Module Mismatch)
Then...
modify the MODULETYPE value.
remove the module and insert one that matches
the expected module type. NOTE: The
pluggable module in LD cards cannot be
replaced without removing the host cards.
remove the module and reseat it back into the
card.
3-27).
3-20). Follow the return
2-193