Trouble-clearing procedures
SWMTXMOD
....................................................................................................................................................................................................................................
SWMTXMOD (Switching Matrix Module Failure)
This condition is applicable to CWR8 cards when the channels going through the card are
not being routed correctly.
In addition, this condition may apply to line cards in the case where there is optical
splitter protection. Communications is present between the working and protection cards,
however, requests (such as a request to turn the laser off) is not implemented. In this case
this condition is raised against the card that is not complying with the request.
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Perform a warm reset on the card where the SWMTXMOD condition is raised.
1
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
2
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
....................................................................................................................................................................................................................................
2-308
Critical
Yes
CWR8
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
config card
Select the card, click the
config card
Select the card, click the
SWMTXMOD (Switching Matrix Module Failure)
3-19).
card type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
reset cold
Reboot
tab, select
Warm Reboot
>
Submit
.
Cold Reboot
>
Submit
.
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011