Trouble-clearing procedures
OCHPDI
....................................................................................................................................................................................................................................
Applicability
Corrective Action
Cleaning the fiber connector of the NE may be service impacting if the fiber is currently
carrying services.
It is recommended to wait for a maintenance window before changing the physical fiber
topology of the NE.
If the OCHPDI condition is exists on a NE for longer than 5 minutes, this means that the
wavelength cannot reach the required target power. This may impact the service in terms
of potential signal quality. In this case, perform the following procedure.
At the end of each step wait to see if the condition clears. If not, continue with the next
step.
...................................................................................................................................................................................................
1
Observe from the condition statement the location and specifications of the condition.
...................................................................................................................................................................................................
Retrieve the listing of cross connects on the NE and determine the service launch points.
2
CLI
WEBUI
...................................................................................................................................................................................................
Open a new window and log into the NEs identified in
3
....................................................................................................................................................................................................................................
2-216
11STAR1, 11STMM10, 11STGE12, 43STA1P, 43STX4,
43STX4P, 4DPA4, MVAC, SVAC
NOTICE
Service-disruption hazard
show xc brief
Select
Connections
Select the desired Cross-Connect.
OCHPDI (Channel Payload Defect Indicator)
>
Cross-Connects
.
Step
2.
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011